MEASURED OUTCOME

Local anesthesia

A procedure-specific topical anesthesia endpoint for cocaine hydrochloride; it does not generalize to systemic stimulant effects.

Findings in context

Measured endpoints are tied to a particular task, population, and exposure. A finding cannot be generalized to a different outcome without supporting evidence.

1 matching findings · Page 1 of 1. Filters search the complete published collection.

Human research · Increased · sourced-draft

In the pivotal randomized trial, anesthetic success occurred in 183/258 participants receiving 4% cocaine hydrochloride versus 25/127 receiving placebo; the 10% arm achieved 210/254.

Population
639 adults requiring diagnostic or surgical procedures involving accessible nasal mucosa
Exposure
Single 20-minute pledget application of 4% or 10% cocaine hydrochloride or placebo
Comparator
Not assessed
Instrument
NPRS pain score of 0 at 20 minutes plus no additional anesthesia or analgesia during the procedure
Magnitude
71% with 4%, 83% with 10%, 20% with placebo.
Assessment time
Not assessed

Connections & claims

Open graph

Each relationship keeps its participants and their roles together. Source details explain what the connection supports.

Claim · not formally assessed

In the pivotal labeled trial, 4% cocaine hydrochloride produced more protocol-defined nasal anesthetic success than placebo.

Single topical pledget application before nasal diagnostic or surgical procedures.

Limitation Patients with important cardiovascular disease or uncontrolled hypertension were excluded, and placebo participants did not proceed to the procedure after unblinding.

Cocaine
outcome observation

Nasal anesthetic success

In the pivotal randomized trial, anesthetic success occurred in 183/258 participants receiving 4% cocaine hydrochloride versus 25/127 receiving placebo; the 10% arm achieved 210/254. 639 adults requiring diagnostic or surgical procedures involving accessible nasal mucosa Single 20-minute pledget application of 4% or 10% cocaine hydrochloride or placebo NPRS pain score of 0 at 20 minutes plus no additional anesthesia or analgesia during the procedure

mechanism observation

Voltage-gated sodium-channel blockade

The U.S. cocaine-hydrochloride label describes reversible blockade of voltage-gated sodium channels, preventing transient sodium conductance and action-potential propagation; this accounts for topical local anesthesia.

clinical benefit

In the pivotal labeled trial, 4% cocaine hydrochloride produced more protocol-defined nasal anesthetic success than placebo.

Single topical pledget application before nasal diagnostic or surgical procedures. Patients with important cardiovascular disease or uncontrolled hypertension were excluded, and placebo participants did not proceed to the procedure after unblinding.

concept mention

Local anesthesia / Stimulant

A procedure-specific topical anesthesia endpoint for cocaine hydrochloride; it does not generalize to systemic stimulant effects.

concept mention

Voltage-gated sodium channel / Local anesthesia

A membrane sodium channel whose state-dependent blockade can reduce action-potential propagation and produce local anesthesia; the cited cocaine label describes reversible voltage-gated sodium-channel blockade as the local-anesthetic mechanism.

Linked substances

1 entries

Articles linked through tags, recorded findings, mechanisms, relationship participants, or shared definition sources. A link alone does not establish a causal effect.

Follow the sources

Definition sources

Publications supporting this definition.

Observation & claim sources

  1. Provides identity of cocaine hydrochloride versus free-base equivalent, approved indication and dosing, pivotal anesthetic trial, pharmacodynamics, pharmacokinetics, abuse/dependence, pregnancy, warnings, and drug interactions.

    Limitation Product labeling concerns controlled topical nasal use and cannot be generalized to unregulated cocaine, other routes, chronic exposure, or polysubstance use.

    Funding not assessedConflicts not assessed

    Funding: Product labeling submitted by the labeler; clinical-program funding was not separately stated in the SPL sections reviewed.

    Conflicts of interest: The document is manufacturer product labeling; no separate academic-author conflict statement applies.

    Source disclosure
    Source in Cocaine